<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-09 13-45-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 46 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 70 kHz 17148 2,4201
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 3,41 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 12 kHz % above 76 kHz: 2,4201 Acquired: 2025/12/09 13.44.46 Total samples: 17148 Equivalent time: 0:14:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,2 dBr MIN: 2,7 dBr AVE: 3,41 dBr % above 12,2 dBr: 0,0 Last value: 4,7 dBr (2025/12/09 13.44.46) 13.30 13.32 13.34 13.36 13.38 13.40 13.42 13.44 0 2 4 6 Pm [dBr]